SpectraPro HRS
The SpectraPro® HRS ensures high spectral resolution, as well as an astigmatism-corrected design for multichannel fiber applications. With dual exit ports the SpectraPro HRS can be used as two array detectors or as both a monochromator and spectrograph.
New ResXtreme Spectral Deconvolution Technology
ResXtreme improves spectral resolution and peak intensity of spectral lines by up to 60%, with an overall improvement in spectral uniformity of 60% at all CCD positions.
Significantly improving signal-to-noise, ResXtreme is included as standard with all SpectraPro HRS systems, ensuring optimal spectral results.
- 60% improvement in spectral resolution and SNR
- Astigmatism-corrected optical system
- Interchangeable grating turrets
- Calibrated with IntelliCal system
- Optimised for multi-detector operation
ResXtreme uses powerful spectral 2D deconvolution to improve spectral resolution and signal-to-noise capabilities.
In this example, spectral resolution improves from 0.0934 nm to 0.0615 nm after ResXtreme. (SpectraPro HRS-300, 1200 g/mm grating, ProEM-HS:1K EMCCD with 10 µm pixels.)
Full-size Dual Focal Planes
The SpectraPro HRS has two ports for the mounting and operation of two cameras, enabling operation as both a monochromator and a spectrograph.
AccuDrive™
AccuDrive™ software is able to automatically identify the turret and gratings installed on start-up performing several optical alignment routines to ensure accurate initialization.
This allows for an improvement in wavelength accuracy and repeatability, outperforming typical scanning systems in accuracy and reproducibility.
Customizable Experimental Set-up
The SpectraPro HRS can be tailored for increased wavelengths (rectangular format sensors) and spectral imaging applications (square format sensors). Both front-and back-illuminated devices, as well as deep depletion devices, allow for multiple experimental set-ups.
The SpectraPro HRS is also compatible with numerous accessories such as light sources, single-channel detectors, fiber optics bundles and filter wheels.
Total Control of Triple-Grating Turret
Access up to 9 gratings using the triple grating turrets. The IsoPlane delivers complete experimental flexibility with software-selectable wavelengths allowing access to any region from the UV to mid-IR range.
Using a single mouse click, diffraction efficiency and resolution can be optimized for any experiment, showcasing the ease and precision of the IsoPlane.
Exclusive High-Performance Optical Coatings
Taking advantage of the Acton #1900 enhanced aluminium optical coating, the SpectraPro HRS has highest reflectivity from UV-IR providing maximum optical system throughput.
The protected silver option provides ≥98% average reflectivity from NIR to 400 nm.
IntelliCal Wavelength Calibration System
With 10x greater wavelength accuracy, the IntelliCal wavelength calibration system uses dual mercury and neon-argon light sources to calibrate wavelengths within the UV-IR range.
The intensity calibration corrects relative intensity of spectra data and removes hardware includes and etaloning effects.
Powered by LightField software
Powerful and intuitive software with built-in math engine allows for the complete control of cameras and spectrographs, with real-time image analysis and spectral data.
LightField software provides seamless integration of hardware controls and direct data acquisition into programmes such as National Instruments’ LabVIEW® and MathWorks’ MATLAB®. This software also fully supports IntelliCal automated wavelength and intensity calibration.
Model Finder
Product | Aperture Ratio | Focal Length | Reciprocal Linear Dispersion | Spectral Resolution [CCD] | Price | Compare | Options |
---|---|---|---|---|---|---|---|
SP-2150
HRS-150
|
f/4 | 150 mm | 4.17 nm/mm | 0.4 nm | In Production Request Info | ||
HRS-500
HRS-500
|
f/6.5 | 500 mm | 1.52 nm/mm | 0.07 nm | In Production Request Info |
|
|
HRS-300
HRS-300
|
f-3.9 | 300 mm | 2.38 nm/mm | 0.10 nm | In Production Request Info |
|
|
HRS-750
HRS-750
|
f/9.7 | 750 mm | 1.03 nm/mm | 0.05 nm | In Production Request Info |
|
Resources & Support
Tech Note
Automated Wavelength and Intensity Calibration Significantly Improves Spectral Accuracy
Read the StoryApplication Note
Scientific NIR-II / SWIR Cameras Enable Femtosecond Frequency Comb Vernier Spectroscopy
Read the StoryBelow are assets shared by all models of this product family.
For model-specific assets, select an option in the Model Finder above.
You must be logged in to download software or firmware. Please sign in or create an account here.
LightField
Below are assets shared by all models of this product family.
For model-specific assets, select an option in the Model Finder above.
SP-2150 Datasheet
SP-2150i Datasheet
SpectraPro-HRS Datasheet
SpectraPro-HRS Grating Datasheet
Contact Technical Support for any queries with your Teledyne Princeton Instruments camera and/or spectrometer, alongside purchasing extended warranty, accessories or software upgrades.